Slogan

Products

Home / Products / Electrical Power Engineering / Electrical Power Systems

Electrical Power Engineering

Electrical Power Systems Lab

  • Generation, Transmission, Distribution & Consumption Stagy
  • Supervision & Control of power system by SCADA software
  • Study of industrial component from global manufacture such as ABB
  • Simulation od real word IEC- Compliant or systems
  • Generator station commissioning & shutdown
  • Logical blocking system (Isolator, Circuit Breakers and the PLC)
  • Turbine operation & characteristics
  • Generator operation characteristics
  • Generator synchronous reactance
  • Transformer short-circuit characteristics
  • Transformer impedance
  • Grid synchronization
  • Turbine control fault
  • Generator/transformer regulator fault
  • Generator/transformer Differential faults
  • Generator stator Earth Faults
  • Transformer neutral point Earth faults
  • Earth Faults
  • Outgoing HV substation Earth Fault
  • Generator load characteristics
  • Generator/transformer excessive loading
  • Generator/transformer load loss fault
  • Programmable dynamic load simulation.
  • Single phase Combined RLC loads
  • Industrial 3 phase loading
  • Load Unbalance
  • Power factor and Reactive power compensation in loads
  • Line vector representation and the Pi model
  • Line model calculation including ISF, impedance scaling factor
  • Cable model calculation including ISF, impedance scaling factor
  • Voltage drop on HV transmission lines
  • Voltage drop on MV transmission lines
  • Voltage drop on MV underground cables
  • Determining line impedance
  • Determining line capacitance
  • Petersen coil earth fault reduction
  • Power quality and reactive compensation on lines
  • Line capacity
  • Connection of double line system (main + backup) to load including fault clearance procedure.
  • Step-down Transformer neutral point Earth faults
  • Substation Earth Faults
  • HV/MV Busbar Earth Faults
  • Phase discontinuity fault: severed MV line fault
  • Outgoing MV Line Auto reclosing
  • Relay protection sectioning , complete system
  • Simulation of Line faults / Feeder faults in complete system
  • Step-down transformer characteristics
  • Blackout, Regional area
  • Blackout, section of a medium sized city
  • Blackout, medium city region
  • Remote access of measurement instruments
  • Remote control of turbine and generator
  • Remote switching of power routes
  • Remote synchronization Remote identification, acknowledgement and clearance of faults
  • Remote fault connection via auxiliary CBs
  • Remote load control
  • Remote parameter setting in IEDs
  • Real-time 3-phase vector presentation on lines
  • Access disturbance records in protections IEDs
  • Disturbance record interpretation of analogue and binary signals
  • Sectioned Generation/Distribution control
  • Building a SCADA page
  • Compensation of inductive loads
  • Dimensioning capacitor banks
  • The C/k parameter
  • Linear switching
  • Cyclic switching – maximize the lifespan of the banks
  • Normally delayed switching
  • Integrally delayed switching
  • Daytime vs. Nighttime power factor correction
  • Power systems in oil drilling rigs & propulsion systems

 

http://www.espranza.org/contents/uploads/2016/02/164.jpg http://www.espranza.org/contents/uploads/2016/02/165.jpg http://www.espranza.org/contents/uploads/2016/02/166.jpg

Espranza Newsletter

Subscribe To Our Newsletter

Enter your email address below to subscribe. You will receive our newsletter once a week.

2016 © All Rights Reserved to Espranza         I         Designed & Developed by  ClickNet